sales3@zcebox.com    +86 13621694523
Cont

Have any Questions?

+86 13621694523

High Quality Residual Current Circuit Breaker with Silver Contact 10ka

High Quality Residual Current Circuit Breaker with Silver Contact 10ka

Standard: IEC 61009-1
Approvals: CE
Type (wave form of the earth leakage sensed): AC, A, s
Send Inquiry

Product Introduction

Our Polyester Distribution Box, ABS Plastic Enclosure, Breaker Box's design and manufacturing technology is continuously improving, and always at the forefront of the industry. As a high-tech enterprise integrating research and development, production and sales, we adhere to the development road of independent innovation, mastering core technology and creating brand. Our products now are widely used in many industries and enjoy a high reputation. We are based on the management policy of "taking talents as support, using technology to obtain benefits, and making brand for development". The company has a first-class professional marketing team.

Features

1. Residual Circuit Breaker is electromagnetic, with all data fully printed on the front, providing long-term identification.

2. The handles of our products can be sealed or equipped with padlock brackets to avoid dangerous operation changes (on/off).

3. Its handle can clearly indicate the contact position, which is intuitive and clear.


Functions

1. Residual Circuit Breaker has switching, isolation and control functions for residential, non-residential, energy, industrial and infrastructure, etc.

2. It can effectively prevent the influence of sinusoidal AC ground fault current, prevent fire hazards caused by insulation faults, and be safer to use.

3. In addition to this, our products have protection against indirect contact and additional protection against direct contact, which further improves the safety during use.


Technical Specifications

Standard: IEC 61009-1

Approvals: CE

Type (wave form of the earth leakage sensed): AC, A, s

Number of poles: 2,4

Rated current ln(A): 16 25 40 63 80 100

Rated voltage Un (VAC): 230/400V

Rated insulation voltage Ui (VAC): 500

Rated frequency Fn (Hz): 50/60

Rated residual currents (mA): It-, n= 10 30 50 100 300

Rated breaking capacity (Icn): Icn of the associated MCB

Rated residual breaking capacity Im: Icn of the associated MCB

Electrical life(times): 6000

Mechanical life(times): 15,000

Degree of protection: IP20, with connected conductors

Conductor Cross-sections

Solid and stranded (mm2): 0.75-35

Finely stranded with end sleeve (mm2): 0.72-25

Terminal tightening torque (N.M): 2.5-4

Ambient temperature(°C): -25~+45,max 95% humidity

Storage temperature(°C): -40~ +75

Altitude Max (meters): Max 2000

Type: Electromagnetic type


Out Line And Installation Dimensions

Accessories Is Introduced

EST button:

TEST button to check the device operability and correct connections.

Connection:

Simultaneous connection by FORK bar and flexible conductor is possible for power supply distribution via upper terminals, as well as connection by PIN bar.

Inner design:

Electromechanical design, without use of electronic components. No power consumption, operability is maintained when neutral conductor is broken.

Notched terminal clamps:

Notched terminal clamps reduce the heat loss and increase mechanical stability of the connection.

Arc suppression chambers:

Arc suppression chambers for each pole ensure more efficient suppression of electric arc.




Number of poles
Rated residual current ln(A)

Rated

Current ln(A)

Type ACType AType S
10

16

LWL1-C16/10-2LWL1-A16/10-2LWL1-S16/10-2
30
16

LWL1-S16/30-2

LWL1-C16/30-2

LWL1-A16/30-2

25

LWL1-C25/30-2

LWL1-A25/30-2

LWL1-S25/30-2

32

LWL1-C40/30-2

LWL1-A40/30-2

LWL1-S40/30-2

63

LWL1-C63/30-2

LWL1-A63/30-2

LWL1-S63/30-2

80

LWL1-C80/30-2

LWL1-A80/30-2

LWLl-S80/30-2

100

LWL1-C100/30-2

LWL1-A100/30-2

LWL1-S100/30-2

100

16

LWL1-S16/100-2

LWL1-C16/100-2

LWL1-A16/100-2

25

LWL1-C25/100-2

LWL1-A25/100-2

LWL1-S25/100-2

32

LWL1-C40/100-2

LWL1-A40/100-2

LWL1-S4OA06-2

63

LWL1-C63/100-2

LWL1-A63/100-2

LWL1-S63/100-2

80

LWL1-C80/100-2

LWL1-A80/100-2

LWL1-S80/100-2

100

LWL1-C100/100-2

LWL1-A100/100-2

LWL1-S100/100-2

300

16

LWLl-S16/300-2

LWL1-C16/300-2

LWL1-A16/300-2

25

LWL1-C25/300-2

LWL1-A25/300-2

LWLl-S25/300-2

32

LWL1-C40/300-2

LWL1-A40/300-2

LWLl-S40/300-2

63

LWL1-C63/300-2

LWL1-A63/300-2

LWL1-S63/300-2

80

LWL1-C80/300-2

LWL1-A80/300-2

LWL1-S80/300-2

100

LWL1-C100/300-2

LWL1-A100/300-2

LWL1-S100/300-2

30

16

LWL1-A16/30-4

LWL1-S16/30-4

LWL1-C16/30-4

25

LWL1-C25/30-4

LWL1-A25/30-4

LWL1-S25/30-4

32

LWL1-C40/30-4

LWL1-A40/30-4

LWL1-S40/30-4

63

LWL1-C63/30-4

LWL1-A63/30-4

LWL1-S63/30-4

80

LWL1-C80/30-4

LWL1-A80/30-4

LWL1-S80/30-4

100

LWL1-C100/30-4

LWL1-A100/30-4

LWL1-S100/30-4

100

16

LWL1-S16/100-4

LWL1-C16/100-4

LWL1-A16/100-4

25

LWL1-C25/100-4

LWL1-A25/100-4

LWL1-S25/100-4

32

LWL1-C40/100-4

LWL1-A40/100-4

LWL1-S40/100-4

63

LWL1-C63/100-4

LWL1-A63/100-4

LWL1-S63/100-4

80

LWL1-C80/100-4

LWL1-A80/100-4

LWL1-S80/100-4

100

LWL1-C100/100-4

LWL1-A100/100-4

LWL1-S100/100-4

300

16

LWL1-S16/300-4

LWL1-C16/300-4

LWL1-A16/300-4

25

LWL1-C25/300-4

LWL1-A25/300-4

LWL1-S25/300-4

32

LWL1-C40/300-4

LWL1-A40/300-4

LWL1-S40/300-4

63

LWL1-C63/300-4

LWL1-A63/300-4

LWL1-S63/300-4

80

LWL1-C80/300-4

LWL1-A80/300-4

LWL1-S80/300-4

100

LWL1-C100/300-4

LWL1-A100/300-4

LWL1-S100/300-4


Types

Both RCCBs and RCBOs are further divided into types depending on the operating function:

1.Type AC :For which tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly rising.

2.Type A : For which tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising

3.Type S :For selectivity, with time-relay.



Tripping Sensitivity Data

1. Rated residual current max. 30 mA for personnel, material and fire protection, as well as protection against direct contact.

2. Rated residual current max. 300 mA for preventive fire protection in case of insulation fault

3. The rated residual current is 100mA, cooperate with the earth system, according to the formula lAn<50/R, provide indirect contact protection again

4. Rated residual current of 10 mA is mainly used in areas that pose an increased risk to personnel.


The total Residual Circuit Breaker in the distribution box should be selected according to the capacity of this power supply, rather than the sum of several loads. The load is changing, and if the load increases in the future, the main switch will also be changed, so each shunt switch protects its own shunt, and the current of the main switch should be determined according to the transformer current or the rated current of the cable.


If you choose a switch, the general household main switch is 32A, and the one with larger power consumption is 64A. The larger household vertical air conditioner is only 4-5KW, and it is one vertical and three wall-mounted.


FAQ

 Q: How is your after sale service

 A: All of our goods conform to certificate of CE, ISO9001, RoHS to guarantee the quality. If you meet any problem when receiving goods, please contact the sales persons who will give you solution in 24 hours.

 Q: Are you a trading company or manufacturer?  

 A: We are a professinal manufacturer with low price,high quality and short delivery time and provide 7x24 service.

 Q: How about the samples?

 A: Sample order is available for quality check and market test. But you have to pay for it.

 Q:  Is it to produce our own brand name?

 A: Sure, we can offer OEM and ODM service.

 Q: How do you control the quality?  

 A: We have professional QA and QC teams, 100% quality inspection is performed before goods out of factory. If need, we can take pictures and video for you to check.


Wining the majority from the crucial certifications of its market for High Quality Residual Current Circuit Breaker with Silver Contact 10ka. Honesty and trustworthiness is the inherent requirement of market economy, which plays an important role in maintaining the order of market economy. We have accumulated a wealth of product knowledge and industry resources, and we understand the principles of product structure and customer needs.

Hot Tags: residual circuit breaker, suppliers, manufacturers, factory, customized, wholesale, price, for sale, free sample, Best MCB, Terminal Junction Box, Junction Box Type, Circuit Breaker MCB, Breaker Box, Waterproof Window For Outdoor Junction Box

Send Inquiry