sales3@zcebox.com    +86 13621694523
Cont

Have any Questions?

+86 13621694523

Korlen Residual Current Circuit Breaker RCCB F360 Series CB 63A

Korlen Residual Current Circuit Breaker RCCB F360 Series CB 63A

Soldered-on material with silver on the contacts.
Notches on the terminal clamps reduce the heat loss and increase mechanical strength of the connection.
The load can be connected to either upper or lower terminals.
Send Inquiry

Product Introduction

Our company with excellent product quality, integrity of the business philosophy and perfect after-sales service, creating a strong brand in the field of Electrical Junction Box PVC, IP65 Junction Box, Distribution box electrical. We believe that performance is not only reflected in the scale of operation and development speed, but also reflected in the improvement of organizational capabilities, the innovation of management models, and the training of outstanding talents. Through long-term tracking and research on new technologies and new customer needs in the industry, we have developed technology research and development directions that are close to the needs of customers.

Overview

LWL1 RCCB is a reliable noise-immune electronic mechanical protective cut-out device that is capable, in contrast to RCCB of type AC,A,S, to ensure a universal protection against electric shock in case of accidental unintentional contact with a conductor and against leakage currents. Circuit Box Plastic has good electrical wear resistance: at least 4000 switching operations. Its rated condition short circuit current is 6000a. It has a wide range of rated current (16, 25, 32, 40, 63, 80100A) and rated trip differential current (30, 100, 300mA).

Circuit Box Plastic uses double latches for quick installation and is silver welded to the material. The slot on the terminal clip reduces the heat loss and improves the mechanical strength of the connection. The load can be connected to the upper or lower terminals. The operation monitoring device has a wide working voltage range (230 ~ 400V).


Functions

Standard: IEC61008-1

Circuit box plastic has passed the CE certification.

Type (wave form of the earth leakage sensed): AC,A

Trip time type: general use, selectivity of S

Number of poles (P): 2,4

Rated current ln(A): 16,25,32,40,63,80,100

Rated voltage Ue (V): 230/400

Storage temperature(C°): -40 ~ +75

Altitude Max(meters): 2,000

Rated insulation voltage Ui (V): 500

Rated frequency Fn (Hz): 50/60

Rated residual currents (IAn)(mA): 10(2P 16A),30,100,300

Rated conditional short-circuit current: Inc=I △ c=6000A SCPD fuse 100A Gg Making and breaking capacity Im (A): 1000

Rated residual breaking capacity I A m (A): 1000

Rated impulse withstand voltage (1.2/50) Uimp (kV): 8

Dielectric test voltage at ind.freq.for 1 min.(kV): 2.5 Electrical life(time): 10,000

Mechanical life(time): 20,000

Degree of protection : IP20,with connected conductors

Mounting position: Any

Conductor cross-sections

Solid and stranded with end sleeve(m㎡):0.75 - 25

Terminal tightening torque(N. m): 2.5-4

Ambient temperature(C°) : -25 ~ +45,max.95% humidity


Overall Dimensions

Features

The rated current is the value of current in amperes (A), which the differential machine is capable of passing through indefinitely without disconnecting the circuit.

The rated voltage is the AC voltage (~ sign) at which the differential machine operates under normal conditions.


Differential current is the current in milliamperes (mA) flowing through the body of a person who has touched a live part and is standing on a conductive floor. To protect against damage, devices with settings of 10, 30 and 100 mA are used. 300 mA devices are used for fire protection or as two-stage selective protection.




LWL1 series RCCB was made stick to IEC61008-1


The terminal of the device has been marked to avoid errors in testing process.

The products have passed the CE certification test and are in line with the European standards for the usage of electrics.



Dual-time interconnection between bus bar and conductor greatly expends the scope of possible circuit solution.

No power consumption, operability is maintained when neutral conductor is broken.

Slices on Mach contact groove prevent wire from overheating and melting due to large contact area.

Screw seals connecting the housing to avoid unauthorized disassembly.


Number of poles
Rated residual current ln(A)

Rated

Current ln(A)

Type ACType AType S
10

16

LWL1-C16/10-2LWL1-A16/10-2LWL1-S16/10-2
30
16

LWL1-S16/30-2

LWL1-C16/30-2

LWL1-A16/30-2

25

LWL1-C25/30-2

LWL1-A25/30-2

LWL1-S25/30-2

32

LWL1-C40/30-2

LWL1-A40/30-2

LWL1-S40/30-2

63

LWL1-C63/30-2

LWL1-A63/30-2

LWL1-S63/30-2

80

LWL1-C80/30-2

LWL1-A80/30-2

LWLl-S80/30-2

100

LWL1-C100/30-2

LWL1-A100/30-2

LWL1-S100/30-2

100

16

LWL1-S16/100-2

LWL1-C16/100-2

LWL1-A16/100-2

25

LWL1-C25/100-2

LWL1-A25/100-2

LWL1-S25/100-2

32

LWL1-C40/100-2

LWL1-A40/100-2

LWL1-S4OA06-2

63

LWL1-C63/100-2

LWL1-A63/100-2

LWL1-S63/100-2

80

LWL1-C80/100-2

LWL1-A80/100-2

LWL1-S80/100-2

100

LWL1-C100/100-2

LWL1-A100/100-2

LWL1-S100/100-2

300

16

LWLl-S16/300-2

LWL1-C16/300-2

LWL1-A16/300-2

25

LWL1-C25/300-2

LWL1-A25/300-2

LWLl-S25/300-2

32

LWL1-C40/300-2

LWL1-A40/300-2

LWLl-S40/300-2

63

LWL1-C63/300-2

LWL1-A63/300-2

LWL1-S63/300-2

80

LWL1-C80/300-2

LWL1-A80/300-2

LWL1-S80/300-2

100

LWL1-C100/300-2

LWL1-A100/300-2

LWL1-S100/300-2

30

16

LWL1-A16/30-4

LWL1-S16/30-4

LWL1-C16/30-4

25

LWL1-C25/30-4

LWL1-A25/30-4

LWL1-S25/30-4

32

LWL1-C40/30-4

LWL1-A40/30-4

LWL1-S40/30-4

63

LWL1-C63/30-4

LWL1-A63/30-4

LWL1-S63/30-4

80

LWL1-C80/30-4

LWL1-A80/30-4

LWL1-S80/30-4

100

LWL1-C100/30-4

LWL1-A100/30-4

LWL1-S100/30-4

100

16

LWL1-S16/100-4

LWL1-C16/100-4

LWL1-A16/100-4

25

LWL1-C25/100-4

LWL1-A25/100-4

LWL1-S25/100-4

32

LWL1-C40/100-4

LWL1-A40/100-4

LWL1-S40/100-4

63

LWL1-C63/100-4

LWL1-A63/100-4

LWL1-S63/100-4

80

LWL1-C80/100-4

LWL1-A80/100-4

LWL1-S80/100-4

100

LWL1-C100/100-4

LWL1-A100/100-4

LWL1-S100/100-4

300

16

LWL1-S16/300-4

LWL1-C16/300-4

LWL1-A16/300-4

25

LWL1-C25/300-4

LWL1-A25/300-4

LWL1-S25/300-4

32

LWL1-C40/300-4

LWL1-A40/300-4

LWL1-S40/300-4

63

LWL1-C63/300-4

LWL1-A63/300-4

LWL1-S63/300-4

80

LWL1-C80/300-4

LWL1-A80/300-4

LWL1-S80/300-4

100

LWL1-C100/300-4

LWL1-A100/300-4

LWL1-S100/300-4

FAQ

 Q: How about the delivery time?

 A: Usually for sample order 3-7 days, or mass order depends on the quality of your orders, usually are 1-e months.

 Q: Would you accept to use our logo?

 A: We can do OEM for you.

 Q: At last, about the payment terms, any convenient and safe way for our buyers?

 A: We have L/C, T/T payment terms options, please rest assure safe business with us.

 Q: 1. What is your package?

 A: We use thermal plastic bag or white carton for packing. We can send to any port where you like.

 Q: 2. How long does the production last?

 A: 20 days for 1X20ft container or 1X40HQ container

 Q: 3. What is your payment terms?

 A: 30% as deposit, and the balance against delivery. (T/T, L/C in EXW, FOB, CNF, CIF...)

 Q: 4. Can we have samples to check?

 A: After the prices confirmed, we can send you a sample for your quality checking. Our sample is for free you only need to afford the shipping cost.


In recent years, our factory is still working hard to open up overseas markets and provide many high-quality, high-demand Korlen Residual Current Circuit Breaker RCCB F360 Series CB 63A for domestic foreign customers. Wherever you are, make sure you join us, and together we will shape a bright future in your business field! We focus and concentrate our efforts, walk steadily and make progress, and adhere to the business philosophy of pragmatism and stability.

Hot Tags: circuit box plastic, suppliers, manufacturers, factory, customized, wholesale, price, for sale, free sample, Surface Mount Electrical Box, Low Voltage Junction Box, Outdoor Distribution Panel Plastic, RCD Circuit Breaker, DIN Rail Junction Box, Electrical Junction Box PVC

Send Inquiry