Dal7-63 6ka RCCB 2p Residual Current Circuit Breaker

Dal7-63 6ka RCCB 2p Residual Current Circuit Breaker

Standard: IEC 61009-1
Approvals: CE
Type (wave form of the earth leakage sensed): AC, A, s
Send Inquiry

Product Introduction

Since our establishment, we have won the respect of our peers, the trust and cooperation of our customers. Our business philosophy is 'professionalism, environmental protection, integrity, and win-win', striving to become the most dazzling star in the field of Surface Mount Electrical Box, DB Box Electrical, IP65 Junction Box! Our factory adheres to the enterprise spirit of 'focusing on morality, pragmatic and innovative', and constantly strengthens the overall quality of the enterprise, and provides good products and services to all sectors of society. Welcome customers to call and contact us. Our company will serve you wholeheartedly based on the tenet of 'customer first, quality assurance, and considerate service'. We welcome potential buyers to contact us.

Features

1. Residual Circuit Breaker is electromagnetic, with all data fully printed on the front, providing long-term identification.

2. The handles of our products can be sealed or equipped with padlock brackets to avoid dangerous operation changes (on/off).

3. Its handle can clearly indicate the contact position, which is intuitive and clear.


Functions

1. Residual Circuit Breaker has switching, isolation and control functions for residential, non-residential, energy, industrial and infrastructure, etc.

2. It can effectively prevent the influence of sinusoidal AC ground fault current, prevent fire hazards caused by insulation faults, and be safer to use.

3. In addition to this, our products have protection against indirect contact and additional protection against direct contact, which further improves the safety during use.


Technical Specifications

Standard: IEC 61009-1

Approvals: CE

Type (wave form of the earth leakage sensed): AC, A, s

Number of poles: 2,4

Rated current ln(A): 16 25 40 63 80 100

Rated voltage Un (VAC): 230/400V

Rated insulation voltage Ui (VAC): 500

Rated frequency Fn (Hz): 50/60

Rated residual currents (mA): It-, n= 10 30 50 100 300

Rated breaking capacity (Icn): Icn of the associated MCB

Rated residual breaking capacity Im: Icn of the associated MCB

Electrical life(times): 6000

Mechanical life(times): 15,000

Degree of protection: IP20, with connected conductors

Conductor Cross-sections

Solid and stranded (mm2): 0.75-35

Finely stranded with end sleeve (mm2): 0.72-25

Terminal tightening torque (N.M): 2.5-4

Ambient temperature(°C): -25~+45,max 95% humidity

Storage temperature(°C): -40~ +75

Altitude Max (meters): Max 2000

Type: Electromagnetic type


Out Line And Installation Dimensions

Accessories Is Introduced

EST button:

TEST button to check the device operability and correct connections.

Connection:

Simultaneous connection by FORK bar and flexible conductor is possible for power supply distribution via upper terminals, as well as connection by PIN bar.

Inner design:

Electromechanical design, without use of electronic components. No power consumption, operability is maintained when neutral conductor is broken.

Notched terminal clamps:

Notched terminal clamps reduce the heat loss and increase mechanical stability of the connection.

Arc suppression chambers:

Arc suppression chambers for each pole ensure more efficient suppression of electric arc.




Number of poles
Rated residual current ln(A)

Rated

Current ln(A)

Type ACType AType S
10

16

LWL1-C16/10-2LWL1-A16/10-2LWL1-S16/10-2
30
16

LWL1-S16/30-2

LWL1-C16/30-2

LWL1-A16/30-2

25

LWL1-C25/30-2

LWL1-A25/30-2

LWL1-S25/30-2

32

LWL1-C40/30-2

LWL1-A40/30-2

LWL1-S40/30-2

63

LWL1-C63/30-2

LWL1-A63/30-2

LWL1-S63/30-2

80

LWL1-C80/30-2

LWL1-A80/30-2

LWLl-S80/30-2

100

LWL1-C100/30-2

LWL1-A100/30-2

LWL1-S100/30-2

100

16

LWL1-S16/100-2

LWL1-C16/100-2

LWL1-A16/100-2

25

LWL1-C25/100-2

LWL1-A25/100-2

LWL1-S25/100-2

32

LWL1-C40/100-2

LWL1-A40/100-2

LWL1-S4OA06-2

63

LWL1-C63/100-2

LWL1-A63/100-2

LWL1-S63/100-2

80

LWL1-C80/100-2

LWL1-A80/100-2

LWL1-S80/100-2

100

LWL1-C100/100-2

LWL1-A100/100-2

LWL1-S100/100-2

300

16

LWLl-S16/300-2

LWL1-C16/300-2

LWL1-A16/300-2

25

LWL1-C25/300-2

LWL1-A25/300-2

LWLl-S25/300-2

32

LWL1-C40/300-2

LWL1-A40/300-2

LWLl-S40/300-2

63

LWL1-C63/300-2

LWL1-A63/300-2

LWL1-S63/300-2

80

LWL1-C80/300-2

LWL1-A80/300-2

LWL1-S80/300-2

100

LWL1-C100/300-2

LWL1-A100/300-2

LWL1-S100/300-2

30

16

LWL1-A16/30-4

LWL1-S16/30-4

LWL1-C16/30-4

25

LWL1-C25/30-4

LWL1-A25/30-4

LWL1-S25/30-4

32

LWL1-C40/30-4

LWL1-A40/30-4

LWL1-S40/30-4

63

LWL1-C63/30-4

LWL1-A63/30-4

LWL1-S63/30-4

80

LWL1-C80/30-4

LWL1-A80/30-4

LWL1-S80/30-4

100

LWL1-C100/30-4

LWL1-A100/30-4

LWL1-S100/30-4

100

16

LWL1-S16/100-4

LWL1-C16/100-4

LWL1-A16/100-4

25

LWL1-C25/100-4

LWL1-A25/100-4

LWL1-S25/100-4

32

LWL1-C40/100-4

LWL1-A40/100-4

LWL1-S40/100-4

63

LWL1-C63/100-4

LWL1-A63/100-4

LWL1-S63/100-4

80

LWL1-C80/100-4

LWL1-A80/100-4

LWL1-S80/100-4

100

LWL1-C100/100-4

LWL1-A100/100-4

LWL1-S100/100-4

300

16

LWL1-S16/300-4

LWL1-C16/300-4

LWL1-A16/300-4

25

LWL1-C25/300-4

LWL1-A25/300-4

LWL1-S25/300-4

32

LWL1-C40/300-4

LWL1-A40/300-4

LWL1-S40/300-4

63

LWL1-C63/300-4

LWL1-A63/300-4

LWL1-S63/300-4

80

LWL1-C80/300-4

LWL1-A80/300-4

LWL1-S80/300-4

100

LWL1-C100/300-4

LWL1-A100/300-4

LWL1-S100/300-4


Types

Both RCCBs and RCBOs are further divided into types depending on the operating function:

1.Type AC :For which tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly rising.

2.Type A : For which tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising

3.Type S :For selectivity, with time-relay.



Tripping Sensitivity Data

1. Rated residual current max. 30 mA for personnel, material and fire protection, as well as protection against direct contact.

2. Rated residual current max. 300 mA for preventive fire protection in case of insulation fault

3. The rated residual current is 100mA, cooperate with the earth system, according to the formula lAn<50/R, provide indirect contact protection again

4. Rated residual current of 10 mA is mainly used in areas that pose an increased risk to personnel.


The total Residual Circuit Breaker in the distribution box should be selected according to the capacity of this power supply, rather than the sum of several loads. The load is changing, and if the load increases in the future, the main switch will also be changed, so each shunt switch protects its own shunt, and the current of the main switch should be determined according to the transformer current or the rated current of the cable.


If you choose a switch, the general household main switch is 32A, and the one with larger power consumption is 64A. The larger household vertical air conditioner is only 4-5KW, and it is one vertical and three wall-mounted.


FAQ

 Q: How is your after sale service

 A: All of our goods conform to certificate of CE, ISO9001, RoHS to guarantee the quality. If you meet any problem when receiving goods, please contact the sales persons who will give you solution in 24 hours.

 Q: Are you a trading company or manufacturer?  

 A: We are a professinal manufacturer with low price,high quality and short delivery time and provide 7x24 service.

 Q: How about the samples?

 A: Sample order is available for quality check and market test. But you have to pay for it.

 Q:  Is it to produce our own brand name?

 A: Sure, we can offer OEM and ODM service.

 Q: How do you control the quality?  

 A: We have professional QA and QC teams, 100% quality inspection is performed before goods out of factory. If need, we can take pictures and video for you to check.


We vigorously expand the domestic and foreign markets, strive to climb the peak of the Dal7-63 6ka RCCB 2p Residual Current Circuit Breaker industry, and develop towards modularization, groupization and internationalization. We continue to improve product quality and seize the market, expand overseas market and increase our market share. By optimizing internal management and reducing production costs, we have not only won our own competitive advantages, but also reduced our customers' operating costs and created win-win benefits.

Hot Tags: residual circuit breaker, suppliers, manufacturers, factory, customized, wholesale, price, for sale, free sample, Junction Box, Junction Box Enclosure, Distribution box electrical, Junction Box Supplier, Electrical Terminal Box, Electrical Junction Box PVC

Send Inquiry