sales3@zcebox.com    +86 13621694523
Cont

Have any Questions?

+86 13621694523

Sc45L-125h RCD Circuit Breaker

Sc45L-125h RCD Circuit Breaker

RCD circuit breaker used in residential building, non-residential building, energy sources, industry and infrastructure, with function of switching, isolation and controlling.
Send Inquiry

Product Introduction

Our Power Breaker Box, electrical equipment, medium voltage junction box is very advantageous since we have introduced a large number of advanced production equipment, with imported high-quality raw materials, and the modern management model in line with international standards. We examine our position, refine our abilities in the context of a fiercely competitive market, and enhance our interaction with the market, so as to obtain better opportunities and space for survival and sustainable development. We will acquire more outstanding talents and technologies, create a dynamic and challenging corporate culture, and build an enterprise with advanced culture, community harmony and shared prosperity. We always adhere to the planned, step-by-step, and reasonable development of business channels, and bind the interests of the majority of enterprises to build a comprehensive business platform. We are adhering to the corporate philosophy of "Working together, innovating and win-win", committed to the construction of a "harmony" culture, focusing on promoting enterprise construction with value, innovation, greenness, responsibility, and happiness as the core connotations, and taking the road of quality development. We welcome customers to come to cooperate and achieve a win-win situation!

Overview

The Breaker Circuit Breaker is electromagnetic and voltage independent. Its handle can be sealed or equipped with padlock bracket to avoid dangerous operation changes. Its handle provides a clear indication of the contact position and fully prints all the data on the front to provide long-term identification. It has a double insulated internal structure and is fixed by screws at the bottom.

The Breaker Circuit Breakers are used in residential, non residential, energy, industrial and infrastructure, with switching, isolation and control functions. It can prevent the influence of sinusoidal AC grounding fault current, indirect contact protection and direct contact additional protection, and prevent insulation fault from causing fire.


Technical Specifications

Standard: IEC 61009-1

Approvals: CE

Type (wave form of the earth leakage sensed): AC, A, S

Number of poles: 2,4

Rated current ln(A): 16 25 40 63 80 100

Rated voltage Un (VAC): 230/400V

Rated insulation voltage Ui (VAC): 500

Rated frequency Fn (Hz): 50/60

Rated residual currents (mA): It-, n= 10 30 50 100 300

Rated breaking capacity (Icn): Icn of the associated MCB

Rated residual breaking capacity Im: Icn of the associated MCB

Electrical life(times): 6000

Mechanical life(times): 15,000

Degree of protection: IP20, with connected conductors

Conductor Cross-sections

Solid and stranded (mm2): 0.75-35

Finely stranded with end sleeve (mm2): 0.72-25

Terminal tightening torque (N.M): 2.5-4

Ambient temperature(°C): -25~+45,max 95% humidity

Storage temperature(°C): -40~ +75

Altitude Max (meters): Max 2000

Type: Electromagnetic type


Out Line And Installation Dimensions

Accessories IS Introduced

TEST button:

TEST button to check the device operability and correct connections.

Connection:

Simultaneous connection by FORK bar and flexible conductor is possible for power supply distribution via upper terminals, as well as connection by PIN bar.


Inner design:

Electromechanical design, without use of electronic components. No power consumption, operability is maintained when neutral conductor is broken.

Notched terminal clamps:

Notched terminal clamps reduce the heat loss and increase mechanical stability of the connection.

Arc suppression chambers:

Arc suppression chambers for each pole ensure more efficient suppression of electric arc.



10

16

LWL6-C16/10-2LWL6-A16/10-2LWL6-S16/10-2
30
16LWL6-C16/30-2LWL6-A16/30-2LWL6-S16/30-2

25

LWL6-C25/30-2

LWL6-A25/30-2

LWL6-S25/30-2

40

LWL6-C40/30-2

LWL6-A40/30-2

LWL6-S40/30-2

63

LWL6-C60/30-2

LWL6-A60/30-2

LWL6-S60/30-2

80

LWL6-C80/30-2

LWL6-A80/30-2

LWL6-S80/30-2

100

LWL6-C100/30-2

LWL6-A100/30-2

LWL6-S100/30-2

100
16LWL6-C16/100-2LWL6-A16/100-2LWL6-S16/100-2

25

LWL6-C25/100-2

LWL6-A25/100-2

LWL6-S25/100-2

40

LWL6-C40/100-2

LWL6-A40/100-2

LWL6-S40/100-2

63

LWL6-C60/100-2

LWL6-A60/100-2

LWL6-S60/100-2

80

LWL6-C80/100-2

LWL6-A80/100-2

LWL6-S80/100-2

100

LWL6-C100/100-2

LWL6-A100/100-2

LWL6-S100/100-2

300
16LWL6-C16/300-2LWL6-A16/300-2LWL6-S16/300-2

25

LWL6-C25/300-2

LWL6-A25/300-2

LWL6-S25/300-2

40

LWL6-C40/300-2

LWL6-A40/300-2

LWL6-S40/300-2

63

LWL6-C60/300-2

LWL6-A60/300-2

LWL6-S60/300-2

80

LWL6-C80/300-2

LWL6-A80/300-2

LWL6-S80/300-2

100

LWL6-C100/300-2

LWL6-A100/300-2

LWL6-S100/300-2

30

16

LWL6-A16/30-4LWL6-C16/30-4LWL6-S16/30-4

25

LWL6-C25/30-4

LWL6-A25/30-4

LWL6-S25/30-4

40

LWL6-C40/30-4

LWL6-A40/30-4

LWL6-S40/30-4

63

LWL6-C60/30-4

LWL6-A60/30-4

LWL6-S60/30-4

80

LWL6-C80/30-4

LWL6-A80/30-4

LWL6-S80/30-4

100

LWL6-C100/30-4

LWL6-A100/30-4

LWL6-S100/30-4

100
16LWL6-S16/100-4

LWL6-C16/100-4

LWL6-A16/100-4

25

40

LWL6-C25/100-4

LWL6-C40/100-4

LWL6-A25/100-4

LWL6-A40/100-4

LWL6-S25/100-4

LWL6-S40/100-4

63

LWL6-C60/100-4

LWL6-A60/100-4

LWL6-S60/100-4

80

LWL6-C80/100-4

LWL6-A80/100-4

LWL6-S80/100-4

100

LWL6-C100/100-4

LWL6-A100/100-4

LWL6-S100/100-4

300

16

LWL6-S16/300-4

LWL6-C16/300-4

LWL6-A16/300-4

25

LWL6-C25/300-4

LWL6-A25/300-4

LWL6-S25/300-4

40

LWL6-C40/300-4

LWL6-A40/300-4

LWL6-S40/300-4

63

LWL6-C60/300-4

LWL6-A60/300-4

LWL6-S60/300-4

80

LWL6-C80/300-4

LWL6-A80/300-4

LWL6-S80/300-4

100

LWL6-C100/300-4

LWL6-A100/300-4

LWL6-S100/300-4


LWB6 MV+MN

Over-voltage and under-voltage release


Application: LWB6

Rated voltage: 230V Variation Uvo=270V+5% Uoe=160V

Function: Protection of the load in the event of a voltage variation of its rated value

LWB6 MX+OF

Shunt release and auxiliary contact

Application: LWB6

Function: Remote opening of the device when a voltage is applied

LWB6 OF

Auxiliary contact

Application: LWB6

Rated current(A): 6

Function: Indication of the position of the device's contacts

LWB6 SD

Auxiliary alarm

Application: LWB6

Rated current(A): 6

Function: Signaling of status making or breaking of MCB and RCD through alarm


FAQ


Q: Can we use our logo?

A: Yes.


Q: Can you open mould?

A: Yes.


Q: what is the payment term?

A: T/T,L/C.


Q:Samples is free of charge?

A: Yes.


Q:what is the lead time?

A: 2-3 days if have stock, 25-30 days for large quantity.


Q:How long is the history of your company ?

A:7 years.


Q: How many employees in your company?

A:150 employees.


Q:Do you receive OEM and ODM?

A:Yes, we can help customer print their logo in the products and help design gift box .


Breaker Circuit Breaker is both switch, is the main components of the distribution cabinet, commonly used air switch, leakage switch, double power automatic conversion switch. Air switch is also the air circuit breaker, in the circuit for connecting, breaking and bearing rated working current and short circuit, overload and other fault current, and can be in the line and load overload, short, road, undervoltage and other circumstances, quickly broken circuit, reliable protection.


Handle the damage of low pressure molded case Breaker Circuit Breaker.

One is the main and auxiliary contact. Severe surface burns should be replaced, so as not to reduce the pressure of the contact surface by too much grinding.

The second is auxiliary contact. The application of fine sandpaper (cloth) No. 00 grinding; No grease on the contact surface.

The third is the arc extinguishing cover. Carbonization phenomenon should be scraped clean; Damp phenomenon should be baked dry; If there is damage, it should be reassembled; Installation Angle should be correct, so as not to hinder contact movement.

Four is the short circuit ring and coil. The damaged ones should be replaced in time. The fifth is the soft connection piece. The damaged components should be replaced in time.


Over the years, we have been committed to the development of the Sc45L-125h RCD Circuit Breaker industry. We have become a very competitive supplier at home and abroad. We are willing to create a better tomorrow with you! We always insist on taking integrity as the foundation of establishment, and take the concept of integrity as the important content of enterprise culture and enterprise management. Our company not only improves the level and level of brand building, but also establishes crisis awareness and strengthens brand crisis management.

Hot Tags: breaker circuit breaker, suppliers, manufacturers, factory, customized, wholesale, price, for sale, free sample, surface mount junction box, Waterproof Electric Junction Box, Electrical Junction Boxes Plastic, 45 amp plastic junction box, 3 way outdoor junction box, Electrical distribution panel box

Send Inquiry