Rmbo6 RCBO RCD/MCB Combined Circuit Breaker Protection 6ka 1p+N None Line/Load Sensitive

Rmbo6 RCBO RCD/MCB Combined Circuit Breaker Protection 6ka 1p+N None Line/Load Sensitive

RCD circuit breaker used in residential building, non-residential building, energy sources, industry and infrastructure, with function of switching, isolation and controlling.
Send Inquiry

Product Introduction

With superb skills and perfect quality assurance system, we are in a leading position in the industry of outdoor electrical box, abb air circuit breaker, pvc enclosure box and are deeply loved by customers. In today's market background of product upgrading and increasingly fierce competition, the success or failure of enterprise competition depends on the overall strength of the enterprise. Sincerely look forward to Win-Win cooperation! Our company's mission is to innovate, to help customers lead step by step to take the initiative to change, to pursue efficiency and to respond quickly and follow suit. Our company is based on the principle of 'customer first, good faith'. Under the condition of guaranteeing and protecting the interests of customers, we are enthusiastic and earnest.

Overview

The Breaker Circuit Breaker is electromagnetic and voltage independent. Its handle can be sealed or equipped with padlock bracket to avoid dangerous operation changes. Its handle provides a clear indication of the contact position and fully prints all the data on the front to provide long-term identification. It has a double insulated internal structure and is fixed by screws at the bottom.

The Breaker Circuit Breakers are used in residential, non residential, energy, industrial and infrastructure, with switching, isolation and control functions. It can prevent the influence of sinusoidal AC grounding fault current, indirect contact protection and direct contact additional protection, and prevent insulation fault from causing fire.


Technical Specifications

Standard: IEC 61009-1

Approvals: CE

Type (wave form of the earth leakage sensed): AC, A, S

Number of poles: 2,4

Rated current ln(A): 16 25 40 63 80 100

Rated voltage Un (VAC): 230/400V

Rated insulation voltage Ui (VAC): 500

Rated frequency Fn (Hz): 50/60

Rated residual currents (mA): It-, n= 10 30 50 100 300

Rated breaking capacity (Icn): Icn of the associated MCB

Rated residual breaking capacity Im: Icn of the associated MCB

Electrical life(times): 6000

Mechanical life(times): 15,000

Degree of protection: IP20, with connected conductors

Conductor Cross-sections

Solid and stranded (mm2): 0.75-35

Finely stranded with end sleeve (mm2): 0.72-25

Terminal tightening torque (N.M): 2.5-4

Ambient temperature(°C): -25~+45,max 95% humidity

Storage temperature(°C): -40~ +75

Altitude Max (meters): Max 2000

Type: Electromagnetic type


Out Line And Installation Dimensions

Accessories IS Introduced

TEST button:

TEST button to check the device operability and correct connections.

Connection:

Simultaneous connection by FORK bar and flexible conductor is possible for power supply distribution via upper terminals, as well as connection by PIN bar.


Inner design:

Electromechanical design, without use of electronic components. No power consumption, operability is maintained when neutral conductor is broken.

Notched terminal clamps:

Notched terminal clamps reduce the heat loss and increase mechanical stability of the connection.

Arc suppression chambers:

Arc suppression chambers for each pole ensure more efficient suppression of electric arc.



10

16

LWL6-C16/10-2LWL6-A16/10-2LWL6-S16/10-2
30
16LWL6-C16/30-2LWL6-A16/30-2LWL6-S16/30-2

25

LWL6-C25/30-2

LWL6-A25/30-2

LWL6-S25/30-2

40

LWL6-C40/30-2

LWL6-A40/30-2

LWL6-S40/30-2

63

LWL6-C60/30-2

LWL6-A60/30-2

LWL6-S60/30-2

80

LWL6-C80/30-2

LWL6-A80/30-2

LWL6-S80/30-2

100

LWL6-C100/30-2

LWL6-A100/30-2

LWL6-S100/30-2

100
16LWL6-C16/100-2LWL6-A16/100-2LWL6-S16/100-2

25

LWL6-C25/100-2

LWL6-A25/100-2

LWL6-S25/100-2

40

LWL6-C40/100-2

LWL6-A40/100-2

LWL6-S40/100-2

63

LWL6-C60/100-2

LWL6-A60/100-2

LWL6-S60/100-2

80

LWL6-C80/100-2

LWL6-A80/100-2

LWL6-S80/100-2

100

LWL6-C100/100-2

LWL6-A100/100-2

LWL6-S100/100-2

300
16LWL6-C16/300-2LWL6-A16/300-2LWL6-S16/300-2

25

LWL6-C25/300-2

LWL6-A25/300-2

LWL6-S25/300-2

40

LWL6-C40/300-2

LWL6-A40/300-2

LWL6-S40/300-2

63

LWL6-C60/300-2

LWL6-A60/300-2

LWL6-S60/300-2

80

LWL6-C80/300-2

LWL6-A80/300-2

LWL6-S80/300-2

100

LWL6-C100/300-2

LWL6-A100/300-2

LWL6-S100/300-2

30

16

LWL6-A16/30-4LWL6-C16/30-4LWL6-S16/30-4

25

LWL6-C25/30-4

LWL6-A25/30-4

LWL6-S25/30-4

40

LWL6-C40/30-4

LWL6-A40/30-4

LWL6-S40/30-4

63

LWL6-C60/30-4

LWL6-A60/30-4

LWL6-S60/30-4

80

LWL6-C80/30-4

LWL6-A80/30-4

LWL6-S80/30-4

100

LWL6-C100/30-4

LWL6-A100/30-4

LWL6-S100/30-4

100
16LWL6-S16/100-4

LWL6-C16/100-4

LWL6-A16/100-4

25

40

LWL6-C25/100-4

LWL6-C40/100-4

LWL6-A25/100-4

LWL6-A40/100-4

LWL6-S25/100-4

LWL6-S40/100-4

63

LWL6-C60/100-4

LWL6-A60/100-4

LWL6-S60/100-4

80

LWL6-C80/100-4

LWL6-A80/100-4

LWL6-S80/100-4

100

LWL6-C100/100-4

LWL6-A100/100-4

LWL6-S100/100-4

300

16

LWL6-S16/300-4

LWL6-C16/300-4

LWL6-A16/300-4

25

LWL6-C25/300-4

LWL6-A25/300-4

LWL6-S25/300-4

40

LWL6-C40/300-4

LWL6-A40/300-4

LWL6-S40/300-4

63

LWL6-C60/300-4

LWL6-A60/300-4

LWL6-S60/300-4

80

LWL6-C80/300-4

LWL6-A80/300-4

LWL6-S80/300-4

100

LWL6-C100/300-4

LWL6-A100/300-4

LWL6-S100/300-4


LWB6 MV+MN

Over-voltage and under-voltage release


Application: LWB6

Rated voltage: 230V Variation Uvo=270V+5% Uoe=160V

Function: Protection of the load in the event of a voltage variation of its rated value

LWB6 MX+OF

Shunt release and auxiliary contact

Application: LWB6

Function: Remote opening of the device when a voltage is applied

LWB6 OF

Auxiliary contact

Application: LWB6

Rated current(A): 6

Function: Indication of the position of the device's contacts

LWB6 SD

Auxiliary alarm

Application: LWB6

Rated current(A): 6

Function: Signaling of status making or breaking of MCB and RCD through alarm


FAQ


Q: Can we use our logo?

A: Yes.


Q: Can you open mould?

A: Yes.


Q: what is the payment term?

A: T/T,L/C.


Q:Samples is free of charge?

A: Yes.


Q:what is the lead time?

A: 2-3 days if have stock, 25-30 days for large quantity.


Q:How long is the history of your company ?

A:7 years.


Q: How many employees in your company?

A:150 employees.


Q:Do you receive OEM and ODM?

A:Yes, we can help customer print their logo in the products and help design gift box .


Breaker Circuit Breaker is both switch, is the main components of the distribution cabinet, commonly used air switch, leakage switch, double power automatic conversion switch. Air switch is also the air circuit breaker, in the circuit for connecting, breaking and bearing rated working current and short circuit, overload and other fault current, and can be in the line and load overload, short, road, undervoltage and other circumstances, quickly broken circuit, reliable protection.


Handle the damage of low pressure molded case Breaker Circuit Breaker.

One is the main and auxiliary contact. Severe surface burns should be replaced, so as not to reduce the pressure of the contact surface by too much grinding.

The second is auxiliary contact. The application of fine sandpaper (cloth) No. 00 grinding; No grease on the contact surface.

The third is the arc extinguishing cover. Carbonization phenomenon should be scraped clean; Damp phenomenon should be baked dry; If there is damage, it should be reassembled; Installation Angle should be correct, so as not to hinder contact movement.

Four is the short circuit ring and coil. The damaged ones should be replaced in time. The fifth is the soft connection piece. The damaged components should be replaced in time.


While giving full play to its own advantages, we continue to introduce advanced technologies and updated management methods at home and abroad to provide customers with better Rmbo6 RCBO RCD/MCB Combined Circuit Breaker Protection 6ka 1p+N None Line/Load Sensitive. We make every effort to build a brand of 'integrity, focus, innovation, and sharing'. Sincerely welcome friends from all walks of life to visit us. We will communicate with you heartily with enthusiasm, strength and sincerity! In line with the principle of honest management, we are aggressive and brave to explore, and constantly get new products and mature market channels, finally win an excellent reputation.

Hot Tags: breaker circuit breaker, suppliers, manufacturers, factory, customized, wholesale, price, for sale, free sample, usb exterior junction box, 12x12x4 pvc junction box, drainage distribution box, 12x12x6 pvc junction box, ip65 enclosure box, Electrical distribution box