sales3@zcebox.com    +86 13621694523
Cont

Have any Questions?

+86 13621694523

MCB 240V AC 50Hz 60Hz 16A 25A 32A 50A 63A Ciruit Breakers

MCB 240V AC 50Hz 60Hz 16A 25A 32A 50A 63A Ciruit Breakers

Soldered-on material with silver on the contacts.
Notches on the terminal clamps reduce the heat loss and increase mechanical strength of the connection.
The load can be connected to either upper or lower terminals.
Send Inquiry

Product Introduction

We will further improve the international market layout and strive to become the most reliable global supplier of Outdoor Distribution Panel Plastic, Waterproof Electric Junction Box, Electrical distribution panel box. Our talent strategy is to provide a development platform for the talents of the world to display their talents, grow rapidly and realize their aspirations. By interacting with our customers, we turn buying and selling into cooperation and elevate business into strategic complementarity.

Overview

LWL1 RCCB is a reliable noise-immune electronic mechanical protective cut-out device that is capable, in contrast to RCCB of type AC,A,S, to ensure a universal protection against electric shock in case of accidental unintentional contact with a conductor and against leakage currents. Circuit Box Plastic has good electrical wear resistance: at least 4000 switching operations. Its rated condition short circuit current is 6000a. It has a wide range of rated current (16, 25, 32, 40, 63, 80100A) and rated trip differential current (30, 100, 300mA).

Circuit Box Plastic uses double latches for quick installation and is silver welded to the material. The slot on the terminal clip reduces the heat loss and improves the mechanical strength of the connection. The load can be connected to the upper or lower terminals. The operation monitoring device has a wide working voltage range (230 ~ 400V).


Functions

Standard: IEC61008-1

Circuit box plastic has passed the CE certification.

Type (wave form of the earth leakage sensed): AC,A

Trip time type: general use, selectivity of S

Number of poles (P): 2,4

Rated current ln(A): 16,25,32,40,63,80,100

Rated voltage Ue (V): 230/400

Storage temperature(C°): -40 ~ +75

Altitude Max(meters): 2,000

Rated insulation voltage Ui (V): 500

Rated frequency Fn (Hz): 50/60

Rated residual currents (IAn)(mA): 10(2P 16A),30,100,300

Rated conditional short-circuit current: Inc=I △ c=6000A SCPD fuse 100A Gg Making and breaking capacity Im (A): 1000

Rated residual breaking capacity I A m (A): 1000

Rated impulse withstand voltage (1.2/50) Uimp (kV): 8

Dielectric test voltage at ind.freq.for 1 min.(kV): 2.5 Electrical life(time): 10,000

Mechanical life(time): 20,000

Degree of protection : IP20,with connected conductors

Mounting position: Any

Conductor cross-sections

Solid and stranded with end sleeve(m㎡):0.75 - 25

Terminal tightening torque(N. m): 2.5-4

Ambient temperature(C°) : -25 ~ +45,max.95% humidity


Overall Dimensions

Features

The rated current is the value of current in amperes (A), which the differential machine is capable of passing through indefinitely without disconnecting the circuit.

The rated voltage is the AC voltage (~ sign) at which the differential machine operates under normal conditions.


Differential current is the current in milliamperes (mA) flowing through the body of a person who has touched a live part and is standing on a conductive floor. To protect against damage, devices with settings of 10, 30 and 100 mA are used. 300 mA devices are used for fire protection or as two-stage selective protection.




LWL1 series RCCB was made stick to IEC61008-1


The terminal of the device has been marked to avoid errors in testing process.

The products have passed the CE certification test and are in line with the European standards for the usage of electrics.



Dual-time interconnection between bus bar and conductor greatly expends the scope of possible circuit solution.

No power consumption, operability is maintained when neutral conductor is broken.

Slices on Mach contact groove prevent wire from overheating and melting due to large contact area.

Screw seals connecting the housing to avoid unauthorized disassembly.


Number of poles
Rated residual current ln(A)

Rated

Current ln(A)

Type ACType AType S
10

16

LWL1-C16/10-2LWL1-A16/10-2LWL1-S16/10-2
30
16

LWL1-S16/30-2

LWL1-C16/30-2

LWL1-A16/30-2

25

LWL1-C25/30-2

LWL1-A25/30-2

LWL1-S25/30-2

32

LWL1-C40/30-2

LWL1-A40/30-2

LWL1-S40/30-2

63

LWL1-C63/30-2

LWL1-A63/30-2

LWL1-S63/30-2

80

LWL1-C80/30-2

LWL1-A80/30-2

LWLl-S80/30-2

100

LWL1-C100/30-2

LWL1-A100/30-2

LWL1-S100/30-2

100

16

LWL1-S16/100-2

LWL1-C16/100-2

LWL1-A16/100-2

25

LWL1-C25/100-2

LWL1-A25/100-2

LWL1-S25/100-2

32

LWL1-C40/100-2

LWL1-A40/100-2

LWL1-S4OA06-2

63

LWL1-C63/100-2

LWL1-A63/100-2

LWL1-S63/100-2

80

LWL1-C80/100-2

LWL1-A80/100-2

LWL1-S80/100-2

100

LWL1-C100/100-2

LWL1-A100/100-2

LWL1-S100/100-2

300

16

LWLl-S16/300-2

LWL1-C16/300-2

LWL1-A16/300-2

25

LWL1-C25/300-2

LWL1-A25/300-2

LWLl-S25/300-2

32

LWL1-C40/300-2

LWL1-A40/300-2

LWLl-S40/300-2

63

LWL1-C63/300-2

LWL1-A63/300-2

LWL1-S63/300-2

80

LWL1-C80/300-2

LWL1-A80/300-2

LWL1-S80/300-2

100

LWL1-C100/300-2

LWL1-A100/300-2

LWL1-S100/300-2

30

16

LWL1-A16/30-4

LWL1-S16/30-4

LWL1-C16/30-4

25

LWL1-C25/30-4

LWL1-A25/30-4

LWL1-S25/30-4

32

LWL1-C40/30-4

LWL1-A40/30-4

LWL1-S40/30-4

63

LWL1-C63/30-4

LWL1-A63/30-4

LWL1-S63/30-4

80

LWL1-C80/30-4

LWL1-A80/30-4

LWL1-S80/30-4

100

LWL1-C100/30-4

LWL1-A100/30-4

LWL1-S100/30-4

100

16

LWL1-S16/100-4

LWL1-C16/100-4

LWL1-A16/100-4

25

LWL1-C25/100-4

LWL1-A25/100-4

LWL1-S25/100-4

32

LWL1-C40/100-4

LWL1-A40/100-4

LWL1-S40/100-4

63

LWL1-C63/100-4

LWL1-A63/100-4

LWL1-S63/100-4

80

LWL1-C80/100-4

LWL1-A80/100-4

LWL1-S80/100-4

100

LWL1-C100/100-4

LWL1-A100/100-4

LWL1-S100/100-4

300

16

LWL1-S16/300-4

LWL1-C16/300-4

LWL1-A16/300-4

25

LWL1-C25/300-4

LWL1-A25/300-4

LWL1-S25/300-4

32

LWL1-C40/300-4

LWL1-A40/300-4

LWL1-S40/300-4

63

LWL1-C63/300-4

LWL1-A63/300-4

LWL1-S63/300-4

80

LWL1-C80/300-4

LWL1-A80/300-4

LWL1-S80/300-4

100

LWL1-C100/300-4

LWL1-A100/300-4

LWL1-S100/300-4

FAQ

 Q: How about the delivery time?

 A: Usually for sample order 3-7 days, or mass order depends on the quality of your orders, usually are 1-e months.

 Q: Would you accept to use our logo?

 A: We can do OEM for you.

 Q: At last, about the payment terms, any convenient and safe way for our buyers?

 A: We have L/C, T/T payment terms options, please rest assure safe business with us.

 Q: 1. What is your package?

 A: We use thermal plastic bag or white carton for packing. We can send to any port where you like.

 Q: 2. How long does the production last?

 A: 20 days for 1X20ft container or 1X40HQ container

 Q: 3. What is your payment terms?

 A: 30% as deposit, and the balance against delivery. (T/T, L/C in EXW, FOB, CNF, CIF...)

 Q: 4. Can we have samples to check?

 A: After the prices confirmed, we can send you a sample for your quality checking. Our sample is for free you only need to afford the shipping cost.


After years of hard work, our company has accumulated rich experience in the MCB 240V AC 50Hz 60Hz 16A 25A 32A 50A 63A Ciruit Breakers industry, and we look forward to cooperating with you sincerely. Welcome to negotiate business. Over the years, relying on the principles of diligence, pragmatism, integrity and thoughtful service, we have established a broad customer base and provided supply for many demand groups. We promote the professional development of skilled personnel with the core of improving vocational quality and professional skills.

Hot Tags: circuit box plastic, suppliers, manufacturers, factory, customized, wholesale, price, for sale, free sample, Residual Circuit Breaker, Waterproof Electric Junction Box, Polyester Distribution Box, RCD Circuit Breaker, Power Distribution Box, Waterproof Junction Box Outdoor

Send Inquiry