Our company always adheres to the enterprise spirit of honesty, truth-seeking, development and innovation and constantly develops new Electrical Junction Box PVC, Plastic Consumer Unit, waterproof electrical box and new markets with excellent technology, innovative technology and leading ideology of the industry. We will create a more brilliant and splendid tomorrow hand in hand with the majority of customers with the business policy of honesty and win-win. We strictly implement the relevant international and domestic quality control system and standards and are committed to providing customers with high-quality products and fast service. Our company is in line with the quality tenet of 'talents, innovation, management, refinement, service' and always pursues the goal of 'high technology, high quality and high efficiency'. Our mission is to pursue the superlative quality, making continual progress.
Overview
LWL1 RCCB is a reliable noise-immune electronic mechanical protective cut-out device that is capable, in contrast to RCCB of type AC,A,S, to ensure a universal protection against electric shock in case of accidental unintentional contact with a conductor and against leakage currents. Circuit Box Plastic has good electrical wear resistance: at least 4000 switching operations. Its rated condition short circuit current is 6000a. It has a wide range of rated current (16, 25, 32, 40, 63, 80100A) and rated trip differential current (30, 100, 300mA).
Circuit Box Plastic uses double latches for quick installation and is silver welded to the material. The slot on the terminal clip reduces the heat loss and improves the mechanical strength of the connection. The load can be connected to the upper or lower terminals. The operation monitoring device has a wide working voltage range (230 ~ 400V).

Functions
Standard: IEC61008-1
Circuit box plastic has passed the CE certification.
Type (wave form of the earth leakage sensed): AC,A
Trip time type: general use, selectivity of S
Number of poles (P): 2,4
Rated current ln(A): 16,25,32,40,63,80,100
Rated voltage Ue (V): 230/400
Storage temperature(C°): -40 ~ +75
Altitude Max(meters): 2,000
Rated insulation voltage Ui (V): 500
Rated frequency Fn (Hz): 50/60
Rated residual currents (IAn)(mA): 10(2P 16A),30,100,300
Rated conditional short-circuit current: Inc=I △ c=6000A SCPD fuse 100A Gg Making and breaking capacity Im (A): 1000
Rated residual breaking capacity I A m (A): 1000
Rated impulse withstand voltage (1.2/50) Uimp (kV): 8
Dielectric test voltage at ind.freq.for 1 min.(kV): 2.5 Electrical life(time): 10,000
Mechanical life(time): 20,000
Degree of protection : IP20,with connected conductors
Mounting position: Any
Conductor cross-sections
Solid and stranded with end sleeve(m㎡):0.75 - 25
Terminal tightening torque(N. m): 2.5-4
Ambient temperature(C°) : -25 ~ +45,max.95% humidity
Overall Dimensions

Features
| The rated current is the value of current in amperes (A), which the differential machine is capable of passing through indefinitely without disconnecting the circuit. |
| The rated voltage is the AC voltage (~ sign) at which the differential machine operates under normal conditions. |
| Differential current is the current in milliamperes (mA) flowing through the body of a person who has touched a live part and is standing on a conductive floor. To protect against damage, devices with settings of 10, 30 and 100 mA are used. 300 mA devices are used for fire protection or as two-stage selective protection. | ||
| LWL1 series RCCB was made stick to IEC61008-1 |
| The terminal of the device has been marked to avoid errors in testing process. |
| The products have passed the CE certification test and are in line with the European standards for the usage of electrics. | ||
| Dual-time interconnection between bus bar and conductor greatly expends the scope of possible circuit solution. |
| No power consumption, operability is maintained when neutral conductor is broken. |
| Slices on Mach contact groove prevent wire from overheating and melting due to large contact area. |
| Screw seals connecting the housing to avoid unauthorized disassembly. |
| Number of poles | Rated residual current ln(A) | Rated Current ln(A) | Type AC | Type A | Type S |
![]() | 10 | 16 | LWL1-C16/10-2 | LWL1-A16/10-2 | LWL1-S16/10-2 |
| 30 | 16 | LWL1-S16/30-2 | LWL1-C16/30-2 | LWL1-A16/30-2 | |
25 | LWL1-C25/30-2 | LWL1-A25/30-2 | LWL1-S25/30-2 | ||
32 | LWL1-C40/30-2 | LWL1-A40/30-2 | LWL1-S40/30-2 | ||
63 | LWL1-C63/30-2 | LWL1-A63/30-2 | LWL1-S63/30-2 | ||
80 | LWL1-C80/30-2 | LWL1-A80/30-2 | LWLl-S80/30-2 | ||
100 | LWL1-C100/30-2 | LWL1-A100/30-2 | LWL1-S100/30-2 | ||
| 100 | 16 | LWL1-S16/100-2 | LWL1-C16/100-2 | LWL1-A16/100-2 | |
25 | LWL1-C25/100-2 | LWL1-A25/100-2 | LWL1-S25/100-2 | ||
32 | LWL1-C40/100-2 | LWL1-A40/100-2 | LWL1-S4OA06-2 | ||
63 | LWL1-C63/100-2 | LWL1-A63/100-2 | LWL1-S63/100-2 | ||
80 | LWL1-C80/100-2 | LWL1-A80/100-2 | LWL1-S80/100-2 | ||
100 | LWL1-C100/100-2 | LWL1-A100/100-2 | LWL1-S100/100-2 | ||
| 300 | 16 | LWLl-S16/300-2 | LWL1-C16/300-2 | LWL1-A16/300-2 | |
25 | LWL1-C25/300-2 | LWL1-A25/300-2 | LWLl-S25/300-2 | ||
32 | LWL1-C40/300-2 | LWL1-A40/300-2 | LWLl-S40/300-2 | ||
63 | LWL1-C63/300-2 | LWL1-A63/300-2 | LWL1-S63/300-2 | ||
80 | LWL1-C80/300-2 | LWL1-A80/300-2 | LWL1-S80/300-2 | ||
100 | LWL1-C100/300-2 | LWL1-A100/300-2 | LWL1-S100/300-2 | ||
![]() | 30 | 16 | LWL1-A16/30-4 | LWL1-S16/30-4 | LWL1-C16/30-4 |
25 | LWL1-C25/30-4 | LWL1-A25/30-4 | LWL1-S25/30-4 | ||
32 | LWL1-C40/30-4 | LWL1-A40/30-4 | LWL1-S40/30-4 | ||
63 | LWL1-C63/30-4 | LWL1-A63/30-4 | LWL1-S63/30-4 | ||
80 | LWL1-C80/30-4 | LWL1-A80/30-4 | LWL1-S80/30-4 | ||
100 | LWL1-C100/30-4 | LWL1-A100/30-4 | LWL1-S100/30-4 | ||
| 100 | 16 | LWL1-S16/100-4 | LWL1-C16/100-4 | LWL1-A16/100-4 | |
25 | LWL1-C25/100-4 | LWL1-A25/100-4 | LWL1-S25/100-4 | ||
32 | LWL1-C40/100-4 | LWL1-A40/100-4 | LWL1-S40/100-4 | ||
63 | LWL1-C63/100-4 | LWL1-A63/100-4 | LWL1-S63/100-4 | ||
80 | LWL1-C80/100-4 | LWL1-A80/100-4 | LWL1-S80/100-4 | ||
100 | LWL1-C100/100-4 | LWL1-A100/100-4 | LWL1-S100/100-4 | ||
| 300 | 16 | LWL1-S16/300-4 | LWL1-C16/300-4 | LWL1-A16/300-4 | |
25 | LWL1-C25/300-4 | LWL1-A25/300-4 | LWL1-S25/300-4 | ||
32 | LWL1-C40/300-4 | LWL1-A40/300-4 | LWL1-S40/300-4 | ||
63 | LWL1-C63/300-4 | LWL1-A63/300-4 | LWL1-S63/300-4 | ||
80 | LWL1-C80/300-4 | LWL1-A80/300-4 | LWL1-S80/300-4 | ||
100 | LWL1-C100/300-4 | LWL1-A100/300-4 | LWL1-S100/300-4 |
FAQ
Q: How about the delivery time?
A: Usually for sample order 3-7 days, or mass order depends on the quality of your orders, usually are 1-e months.
Q: Would you accept to use our logo?
A: We can do OEM for you.
Q: At last, about the payment terms, any convenient and safe way for our buyers?
A: We have L/C, T/T payment terms options, please rest assure safe business with us.
Q: 1. What is your package?
A: We use thermal plastic bag or white carton for packing. We can send to any port where you like.
Q: 2. How long does the production last?
A: 20 days for 1X20ft container or 1X40HQ container
Q: 3. What is your payment terms?
A: 30% as deposit, and the balance against delivery. (T/T, L/C in EXW, FOB, CNF, CIF...)
Q: 4. Can we have samples to check?
A: After the prices confirmed, we can send you a sample for your quality checking. Our sample is for free you only need to afford the shipping cost.
With the continuous upgrading of product series, we will provide more high-quality DC DIN Rail Switch Solar Energy PV 4p 50A 63A MCB Breaker solutions to more customers around the world. Our company has always put the interests of customers above our own interests, and has been widely praised. Thank you for every opportunity, thank you for your affirmation, and thank you for your trust every time!
Hot Tags: circuit box plastic, suppliers, manufacturers, factory, customized, wholesale, price, for sale, free sample, 4x4x2 wall sconce electrical box, 50 amp power distribution box, MCB Breaker, Junction Box Enclosure, 20a rectangular junction box, aircraft circuit breakers