Soldered-on material with silver on the contacts.
Notches on the terminal clamps reduce the heat loss and increase mechanical strength of the connection.
The load can be connected to either upper or lower terminals.
Send Inquiry

Product Introduction

We pay close attention to concept innovation, improve Waterproof Electric Junction Box, Breaker Box, Waterproof Junction Box quality, highlight our characteristics, so as to broaden our market. Providing first class products is our aim. We uses the e-commerce system to strengthen and promote customer relationship management, customer business operation, customer service and information communication. We are willing to provide you with 100% satisfactory service with excellent quality, advanced technology, cost-effective products, and a professional team.

Overview

LWL1 RCCB is a reliable noise-immune electronic mechanical protective cut-out device that is capable, in contrast to RCCB of type AC,A,S, to ensure a universal protection against electric shock in case of accidental unintentional contact with a conductor and against leakage currents. Circuit Box Plastic has good electrical wear resistance: at least 4000 switching operations. Its rated condition short circuit current is 6000a. It has a wide range of rated current (16, 25, 32, 40, 63, 80100A) and rated trip differential current (30, 100, 300mA).

Circuit Box Plastic uses double latches for quick installation and is silver welded to the material. The slot on the terminal clip reduces the heat loss and improves the mechanical strength of the connection. The load can be connected to the upper or lower terminals. The operation monitoring device has a wide working voltage range (230 ~ 400V).


Functions

Standard: IEC61008-1

Circuit box plastic has passed the CE certification.

Type (wave form of the earth leakage sensed): AC,A

Trip time type: general use, selectivity of S

Number of poles (P): 2,4

Rated current ln(A): 16,25,32,40,63,80,100

Rated voltage Ue (V): 230/400

Storage temperature(C°): -40 ~ +75

Altitude Max(meters): 2,000

Rated insulation voltage Ui (V): 500

Rated frequency Fn (Hz): 50/60

Rated residual currents (IAn)(mA): 10(2P 16A),30,100,300

Rated conditional short-circuit current: Inc=I △ c=6000A SCPD fuse 100A Gg Making and breaking capacity Im (A): 1000

Rated residual breaking capacity I A m (A): 1000

Rated impulse withstand voltage (1.2/50) Uimp (kV): 8

Dielectric test voltage at ind.freq.for 1 min.(kV): 2.5 Electrical life(time): 10,000

Mechanical life(time): 20,000

Degree of protection : IP20,with connected conductors

Mounting position: Any

Conductor cross-sections

Solid and stranded with end sleeve(m㎡):0.75 - 25

Terminal tightening torque(N. m): 2.5-4

Ambient temperature(C°) : -25 ~ +45,max.95% humidity


Overall Dimensions

Features

The rated current is the value of current in amperes (A), which the differential machine is capable of passing through indefinitely without disconnecting the circuit.

The rated voltage is the AC voltage (~ sign) at which the differential machine operates under normal conditions.


Differential current is the current in milliamperes (mA) flowing through the body of a person who has touched a live part and is standing on a conductive floor. To protect against damage, devices with settings of 10, 30 and 100 mA are used. 300 mA devices are used for fire protection or as two-stage selective protection.




LWL1 series RCCB was made stick to IEC61008-1


The terminal of the device has been marked to avoid errors in testing process.

The products have passed the CE certification test and are in line with the European standards for the usage of electrics.



Dual-time interconnection between bus bar and conductor greatly expends the scope of possible circuit solution.

No power consumption, operability is maintained when neutral conductor is broken.

Slices on Mach contact groove prevent wire from overheating and melting due to large contact area.

Screw seals connecting the housing to avoid unauthorized disassembly.


Number of poles
Rated residual current ln(A)

Rated

Current ln(A)

Type ACType AType S
10

16

LWL1-C16/10-2LWL1-A16/10-2LWL1-S16/10-2
30
16

LWL1-S16/30-2

LWL1-C16/30-2

LWL1-A16/30-2

25

LWL1-C25/30-2

LWL1-A25/30-2

LWL1-S25/30-2

32

LWL1-C40/30-2

LWL1-A40/30-2

LWL1-S40/30-2

63

LWL1-C63/30-2

LWL1-A63/30-2

LWL1-S63/30-2

80

LWL1-C80/30-2

LWL1-A80/30-2

LWLl-S80/30-2

100

LWL1-C100/30-2

LWL1-A100/30-2

LWL1-S100/30-2

100

16

LWL1-S16/100-2

LWL1-C16/100-2

LWL1-A16/100-2

25

LWL1-C25/100-2

LWL1-A25/100-2

LWL1-S25/100-2

32

LWL1-C40/100-2

LWL1-A40/100-2

LWL1-S4OA06-2

63

LWL1-C63/100-2

LWL1-A63/100-2

LWL1-S63/100-2

80

LWL1-C80/100-2

LWL1-A80/100-2

LWL1-S80/100-2

100

LWL1-C100/100-2

LWL1-A100/100-2

LWL1-S100/100-2

300

16

LWLl-S16/300-2

LWL1-C16/300-2

LWL1-A16/300-2

25

LWL1-C25/300-2

LWL1-A25/300-2

LWLl-S25/300-2

32

LWL1-C40/300-2

LWL1-A40/300-2

LWLl-S40/300-2

63

LWL1-C63/300-2

LWL1-A63/300-2

LWL1-S63/300-2

80

LWL1-C80/300-2

LWL1-A80/300-2

LWL1-S80/300-2

100

LWL1-C100/300-2

LWL1-A100/300-2

LWL1-S100/300-2

30

16

LWL1-A16/30-4

LWL1-S16/30-4

LWL1-C16/30-4

25

LWL1-C25/30-4

LWL1-A25/30-4

LWL1-S25/30-4

32

LWL1-C40/30-4

LWL1-A40/30-4

LWL1-S40/30-4

63

LWL1-C63/30-4

LWL1-A63/30-4

LWL1-S63/30-4

80

LWL1-C80/30-4

LWL1-A80/30-4

LWL1-S80/30-4

100

LWL1-C100/30-4

LWL1-A100/30-4

LWL1-S100/30-4

100

16

LWL1-S16/100-4

LWL1-C16/100-4

LWL1-A16/100-4

25

LWL1-C25/100-4

LWL1-A25/100-4

LWL1-S25/100-4

32

LWL1-C40/100-4

LWL1-A40/100-4

LWL1-S40/100-4

63

LWL1-C63/100-4

LWL1-A63/100-4

LWL1-S63/100-4

80

LWL1-C80/100-4

LWL1-A80/100-4

LWL1-S80/100-4

100

LWL1-C100/100-4

LWL1-A100/100-4

LWL1-S100/100-4

300

16

LWL1-S16/300-4

LWL1-C16/300-4

LWL1-A16/300-4

25

LWL1-C25/300-4

LWL1-A25/300-4

LWL1-S25/300-4

32

LWL1-C40/300-4

LWL1-A40/300-4

LWL1-S40/300-4

63

LWL1-C63/300-4

LWL1-A63/300-4

LWL1-S63/300-4

80

LWL1-C80/300-4

LWL1-A80/300-4

LWL1-S80/300-4

100

LWL1-C100/300-4

LWL1-A100/300-4

LWL1-S100/300-4

FAQ

 Q: How about the delivery time?

 A: Usually for sample order 3-7 days, or mass order depends on the quality of your orders, usually are 1-e months.

 Q: Would you accept to use our logo?

 A: We can do OEM for you.

 Q: At last, about the payment terms, any convenient and safe way for our buyers?

 A: We have L/C, T/T payment terms options, please rest assure safe business with us.

 Q: 1. What is your package?

 A: We use thermal plastic bag or white carton for packing. We can send to any port where you like.

 Q: 2. How long does the production last?

 A: 20 days for 1X20ft container or 1X40HQ container

 Q: 3. What is your payment terms?

 A: 30% as deposit, and the balance against delivery. (T/T, L/C in EXW, FOB, CNF, CIF...)

 Q: 4. Can we have samples to check?

 A: After the prices confirmed, we can send you a sample for your quality checking. Our sample is for free you only need to afford the shipping cost.


Our company's business has spread all over the world. We are working hard to become a benchmark enterprise in China Supplier 1 Pole to 4 Pole MCB 1000V DC Breaker industry. We seek sincere cooperation in a wide range of fields, relying on good reputation, high-quality products, and low prices to serve customers. We build our brand with good corporate reputation, pragmatic dedication and rigorous work attitude.

Hot Tags: circuit box plastic, suppliers, manufacturers, factory, customized, wholesale, price, for sale, free sample, DB Box Electrical, Electrical distribution box, Surface Mount Electrical Box, Electrical Terminal Box, Circuit Breaker MCB, Power Distribution Box

Send Inquiry