Our company strives to provide the best overall solution and the best quality service for enterprises in the market environment of labor shortage and quickly improve the quality and production efficiency of ABS Plastic Enclosure, Best MCB, DIN Rail Junction Box. Employees are the internal driving force of our company's sustainable development, which is based on the foundation stone of people-oriented happiness culture. We hope to build our enterprise into a comprehensive construction group with first-class competitiveness and influence. Respecting talents, cultivating talents, making good use of talents and creating an environment for excellent talents to give full play to their talents are important factors for the healthy and rapid development of our company.
Features
1. The handle of circuit breaker amp is being sealable or equipped with padlock bracket avoids dangerous operation changes (ON/OFF).
2. The handle provides a clear indication of the contact position.
3. Adequate printing of all data on the front provides long-term identification.
4. Energy limiting class of circuit breaker switch: 3.
5. The emission of ionized gases is limited to the severest restrictions: 45 mm grid distance.
6. This circuit breaker amp for household in accordance with IEC60898 - B C and D tripping characteristics.
7. This MCB circuit breakers for industry in accordance with IEC60947-2 instantaneous tripping characteristics with release B: 4ln, release C: 8ln, release D: 12ln
8. This MCB mini circuit breakers may be extended with:
A wide range of RCDs
Full sets of additional components
Full sets of accessories


Functions
-Overload protection
-Short circuit protection
-Isolation -Controlling
Circuit breaker amp used in residential building, non-residential building, industry, energy infrastructure
Technical Specifications
Standard: IEC60898-1, IEC60947-2
Approvals: CE
Rated Current ln(A): 6,10,16,20,25,32,40,50,63
Rated Voltage Un: AC 230/400V DC 250V/500V
Rated Frequency (Hz): 50/60
Number Of Poles: 1,2,3,4
Tripping Characteristic: B,C,D
Characteristic Curve B (In): 3 - 5
Characteristic Curve C (In): 5 -10
Characteristic Curve D (In): 10 -20
Rated Switching Capacity Icn (A): 6000
Degree Of Protection: IP20, with connected conductors
Electrical Life(times): 6,000
Mechanical Life(times): 15,000
Breaking Capacity
Fire Resistance According To UL 94: V0
Mounting Position: Any
Cross-sections Of Wire (mm2) : 25
Terminal Tightening Torque (N.M) : 2.5
Working Environment Temperature(°C) : -40~ +50,max 95% humidity
Altitude (meters) : Max 2000
Tripping Characteristic Curves
• IEC60898-1 Standard
| • Magnetic release An electromagnet with plunger ensures instantaneous tripping in case of short circuit. The IEC 60898 distinguishes three different types, following the current for instantaneous release: type B, C, D
|
TEST CURRENT | TRIPPING TIME | APPLICATIONS | |
B | 3 In 5 In | 0.1<t<45s(ln<32A) 0.1<t<90s(ln>32A) t<0.1s· | Only for resistive loads such as: -electrical heating -water heater -stoves loads such as |
C | 5 In 10 In | 0.1<t<15s(ln<32A) 0.1<t<30s(ln>32A) | Usual loads such as: -lighting -socket outlets -small motors |
D | 10 In 20 In | 0.1<t<4s(ln<32A) 0.1<t<8s(ln>32A) t<0.1s | Control and protection of circuits having important transient inrush currents (large motors) |
• Thermal Release
-The release is initiated by a bimetal strip in case of overload
-The standard defines the range of release of specific overload values
-Reference ambient temperature is 30°C
TEST CURRENT | TRIPPING TIME |
1.13 In | t>1h (ln<63A) |
1.45 In | t<1h (ln<63A) |
2.55 In | ls<t<60s(ln<32A) ls<t<120s(ln>32A) |
• IEC60947-2 STANDARD
| • Magnetic release -An electromagnet with plunger ensures instantaneous tripping in case of short circuit. -The standard leaves the calibration of magnetic release to manufacturers decision. -LWBX offers instantaneou's tripping ranges -release B: 4ln -release C: 8ln -release D: 12ln |
• Thermal Release
-The release is initiated by a bimetal strip in case of overload
-The standard defines the range of release for two specific overload values -Reference ambient temperature is 30°C for LWBX
TEST CURRENT | TRIPPING TIME |
1.05 In | t>lh (ln<63A) |
1.30 In | t<lh (ln<63A) |
• Accessories Is Introduced
Rated Current: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;C is the action curve; Band limited current protection |
Breaking Capacity: 6000A |
Rated voltage: AC 230/400V DC 250V/500V; The indicator window includes on and off. |
Handle: Fast closing function can be selected according to customer's requirements. |
Accessory: Assembly type buckle. There are attachments such as MV SDOF MN MVADN MN. |
Raw Material: Toyo Dongli high temperature PPS material, ensure temperature resistance and no deformation. |
Our exhibition

FAQ
Q:What advantage do you have?
A:We are the factory and we have 11 years experience in foreign trade.
Q: How long is the quality guarantee?
A:It usually 2-3years, depend on different goods.
Q: What's the price?
A:Different items different market will be different cost, we will keep to give best and competitive price for each customer.
Q:How do we know you are a reliable supplier?
A:As a professional manufacturer we do good quality to cooperate with many countries,such as Russia,Brazil,US,Dubai and so on.
Q: Which shipping method do you provide?
A:For samples or small orders, goods will be sent by express.
For regular orders, goods can be sent by air or by sea, just according to your demand.
We are strict about the quality of our 100A Portable Micro Ohm Meter Loop Resistance Contact Resistance Circuit Breaker Tester for High Voltage Switchgear Touch Screen LCD, because it is our aim to provide quality products and services to our customers. In the face of complex market competition, we always adhere to the business tenet of quality first and customer first, and serve our customers wholeheartedly to develop together. Make sure provide the best Service, the Best Quality, The fast Delivery.
Hot Tags: circuit breaker amp, suppliers, manufacturers, factory, customized, wholesale, price, for sale, free sample, Distribution box electrical, Terminal Junction Box, Electrical distribution panel box, Electric Circuit Breaker, MCB Distribution Box, Breaker Box