Standard:IEC60439-3
Approval:CE,RoHS,HF test,IK test,ISO
Protection deqree:IP40
Mounting type:flush and surface
Storage temperature:-40~+75
Amebient temperature (℃ ): -5~+40, max.95%humidity

breaker plastic distribution box Internal structure: installed in the internal for fixed terminal box, circuit breaker installation rail, so that you install more convenient.
Sealing ring: reinforced sealing bar made of polyamine acid material, high corrosion resistance, better waterproof and longer life.
Window design: PC transparent material clamshell window, more intuitive, dense, better sealing.
Plain packing box: smooth and beautiful appearance, no mottled spots.

breaker plastic distribution box
1, board 1RABS material, high strength, transparent material for PC.
2. The cover of the distribution box is pressed to open and close. Just gently press the mask to open and uncover the hinge structure with self-locking position.
3, distribution box line design can be the guide rail support plate up to the high point of the activity, the installation of wire is no longer limited by the narrow space, so that the installation of easy distribution box switch is provided with a line slot, line pipe hole, easy to use all kinds of line slot, pipe.

When the equipment of the Breaker Plastic Distribution Box fails, it is likely to affect our normal electricity consumption, so how to solve the fault of the distribution box
Solution 1: Motor failure
If the motor windings are burnt, there will be smoke, odor, fuse blown, etc. If there is voltage at both ends of the motor and the motor does not rotate, it may be caused by the failure of the carbon brushes falling off or being severely worn.
Solution 2: Improper adjustment of the travel switch
The limit switch is a limit switch that controls the energy storage position of the motor. The fault phenomenon is: the motor does not stop when idling, and the energy storage indicator does not light up. Only by turning on the control switch can the motor stop. When the limit adjustment is too low, the motor will stop before the energy storage is full. Since the switch cannot be closed because the energy storage is not in place, the method of adjusting the limit is to manually store energy slowly to find the correct position and tighten it.
Solution three, control switch failure
When the control switch is damaged so that the circuit cannot be closed and the control circuit is disconnected and the circuit is open, the fault manifestations are that the motor does not rotate and there is no voltage at both ends of the motor. The search method is to use a multimeter to measure the voltage or resistance. When using the resistance measurement method, pay attention to the on and off of the bypass. If there is a bypass parallel circuit, one end of the line to be tested should be disconnected; the voltage measurement method is when the control circuit is energized, The multimeter is adjusted to the voltage range, if there is voltage, there is an open circuit point between the two points to be measured.
Hot Tags: breaker plastic distribution box, suppliers, manufacturers, factory, customized, wholesale, price, for sale, free sample